Clamp meter calibration · Mining

Clamp meter calibration for mining

Clamp meters on a mine site are used for motor current checks, load balancing and fault finding on plant that cannot be shut down for a series measurement. Dust in the jaw faces is the most common reason a site clamp reads low.

A clamp meter reads current without breaking the circuit, which makes it the default tool for load surveys and motor checks — and makes its accuracy hard to sanity-check in the field. AmpTech calibrates AC and DC clamp meters in our Caversham lab, driving known currents through the jaw from a traceable reference and checking the meter's other functions at the same time.

Interval in mining

12 months

Manufacturer default; shorten for dusty plant

Setting the interval

Twelve months is standard. Clamps used for energy audits or for readings that feed into invoicing or reports are often kept on a tighter interval because the current reading is the product.

What the calibration covers

  • AC current at points up to 11 A, the ceiling our calibrator sources directly
  • DC current on Hall-effect clamps, including zero offset after the jaw is opened and closed
  • Voltage and resistance functions where the meter provides them
  • Frequency and inrush functions where fitted
  • Jaw closure and alignment — a jaw that does not close cleanly reads low

What your certificate records

The certificate format mining procurement and audit teams ask for: the equipment under test, its serial number, the reference instruments used, as-found and as-left readings, environmental conditions and a traceability statement, plus the clamp meter-specific items below.

  • As-found and as-left current readings at each test point and range
  • Results for voltage, resistance and any other functions tested
  • Reference current source and other standards used
  • Environmental conditions at the time of calibration

Standards & frameworks in mining

  • ISO 9001 quality management system
  • AS/NZS 3760 for portable electrical equipment on site
  • WHS (Mines) Regulations 2022 (Western Australia)
  • Operator-specific prequalification requirements

How mining clients get clamp meters to us

Calibration is performed in our Caversham lab — not on site. We collect from and deliver back to mining workshops and offices across Perth, and instruments from regional sites come by freight or via your Perth base.

  • Mining head offices in Perth CBD and West Perth
  • Welshpool / Kewdale freight and equipment hubs supporting Pilbara operations
  • Malaga and Bayswater workshops fitting out mine vehicles and tooling
  • FIFO bases at Perth Airport — fast-turn calibration before flights out

Working with mining procurement

We work with mining procurement teams on POs, prequalification packs and instrument-by-instrument quotes. Every calibration ships with a clear certificate showing as-found / as-left readings and a traceability statement — exactly what auditors and PMC reviews ask to see.

FAQ

Clamp meter calibration for mining FAQs

Should we send the clamp meters with our multimeters?
Yes — most sites run them on the same recall date and we calibrate them in the same batch, so they come back together with one register covering the lot.
Do you calibrate the current clamp or just the meter functions?
Both. The current clamp is calibrated by passing known currents through the jaw from a traceable source, and the voltage, resistance and other functions are checked separately.
How much current can you actually apply through the jaw?
Up to 11 A, which is what our calibrator sources directly. That covers the low current ranges most clamps are read on day to day, and your certificate states exactly which points were tested. If you need the 200 A or 600 A ranges verified, tell us when you enquire — we will say so plainly rather than imply a range we did not test.